PWX- 04525

PWX-
04525

Invalid combination of condense files or types detected.
This error occurs when you attempt to extract change data for:
  • Capture registrations with different condense types (none, partial, or full)
  • A single capture registration with changes in both full and partial condense files
The request fails.
If you are using group source to extract change data from condense files, separate the capture registrations so that only a single condense type is included in the extraction. Include capture registrations with a condense type of Full in one extraction, a condense type of None in another extraction, and a condense type of Partial in a different extraction. Run these extractions separately.
If a condense type for a specific capture registration was changed between Full and Partial, then additional action is required. You must either recondense the data into a single type of condense file or you must change the extraction start point to skip over the condense files of the previous condense type. Before altering the capture registration to change the condense type, extract all data.
If the issue cannot be resolved, contact Informatica Global Customer Support.