PWX- 06811

PWX-
06811

Journal code
journal_entry_type_code
specified for both ADDLIB and DLTLIB values on AS400USRJRNCODE statement.
In the AS400USRJRNCODE statement of the DBMOVER member, the same journal entry type code is specified for the ADDLIB and DLTLIB parameters. You must enter a unique, two-character code for each parameter. PowerExchange uses these entries to identify SNDPWXJRNE add library and delete library entries in a DB2 for
i5/OS
user journal for refreshing the CDC library interest list.
The task ends.
In the AS400USRJRNCODE statement, enter different values for the ADDLIB and DLTLIB parameters. These values must be two characters in length.