PWX- 03062

PWX-
03062

Optional fields cannot be written to fixed-length file
record_name
. File RECFM
record_format
.
The target output file has a fixed-length record format as specified in the message. The data map contains optional fields that cannot be written to a fixed-length record. Message PWX-03060 identifies the optional field name.
Processing ends.
To resolve this issue, clear the
Optional Field
attribute or set the target file to a variable-length record format.