PWX-03022

PWX-
03022

Log record from an IMS FLD call for a complex table registration
registration_name
found. Log record time=
lrsn
timestamp
.
A PowerExchange process that extracts change data from PowerExchange Logger log files found a logged change record that was produced by an IMS FLD call against a low-level segment in the specified complex table registration. The extraction gets change data only for the low-level segment and sets all of the parent segments to 0.
PowerExchange provides data only for the low-level segment for which the FLD call captured data.
In the PowerExchange Navigator, select the
Generate CCK Columns
option in the data map for the complex table to ensure that PowerExchange generates the concatenated key (CCK) for the low-level segment. The CCK is required to properly apply the data that was captured from the low-level segment.