PowerExchange for CDC and Mainframe
- PowerExchange for CDC and Mainframe 10.5.2
- All Products
Reason Code
| Explanation
|
---|---|
01800101
| An invalid data type was found during an OPEN call.
|
01800102
| The GET and PUT functions require an open token.
|
01800103
| An invalid IPC header was found.
|
01800104
| A prior error requires CIC to stop. For more information, see the previous error.
|
01800105
| No create token was provided.
|
01800106
| A global queue error occurred.
|
01800107
| The PowerExchange Agent is not active
|
01800108
| The mailman task ended prematurely.
|
01800109
| An error occurred in the mailman.
|
0180010A
| The 'mailman ended' flag is on.
|
0180010C
| The BUILD CDE function failed.
|
0180010D
| The DELETE CDE function failed.
|
01810101
| CIC is being forced to terminate.
|
01810102
| A global queue error occurred.
|
01810103
| An error occurred during resync processing.
|
01810104
| A cross‑memory post failed.
|
01810105
| The PowerExchange Logger quit during the termination process.
|
01810106
| The PowerExchange Logger is inactive, and the global directory (EDMSDIR) requested an abend. This code is returned during initialization in an offline environment.
|
01810107
| The caller requested that CIC post all units of work.
|
01810108
| The PowerExchange Logger has ended.
|
01810109
| The PowerExchange Logger is inactive, and the global directory (EDMSDIR) requested an abend. This code is returned during sync point processing in online IMS and CICS environments.
|
0181010A
| The PowerExchange Logger terminated before the ECCR could connect to the logger.
|
0181010B
| An XCF JOIN function failed.
|
0181010C
| An XCF LEAVE function failed.
|
0181010D
| An XCF PUT function failed.
|
0181010E
| An XCF GET function failed.
|
0181010F
| An XCF FREE BUFFER failed.
|
01810110
| An error occurred when CIC attempted to open a logger queue.
|
01810111
| The logger terminated during CIC initialization.
|
01820101
| The module was unable to get into a supervisory state.
|
01820102
| A name/token CREATE failed.
|
01820103
| A name/token RETRIEVE failed.
|
01820104
| A name/token DELETE failed.
|
01820105
| The BUILD CDE function failed.
|
01820106
| The DELETE CDE function failed.
|
01820107
| An error occurred when connecting to common services.
|
01820108
| A disconnect error from common services occurred.
|
01820109
| CIC is loading the program to CSA.
|
0182010A
| Initialization for the module EDMCICLG failed.
|
0182010B
| The PUT function for the module EDMCICLG failed.
|
0182010C
| Termination for the module EDMCICLG failed.
|
0182010D
| A cross‑memory post failed.
|
01830101
| An error was returned from the mailman.
|
01830102
| A name/token RETRIEVE failed.
|
01830103
| An invalid length was passed.
|
01830104
| The object's profile was not found.
|
01830105
| The mailman has ended.
|
01830106
| The PowerExchange Agent was unavailable during initialization.
|
01830107
| The PowerExchange Agent was unavailable during a registration call.
|
01840101
| An error occurred when connecting to common services.
|
01840102
| The SET STIMERM function failed.
|
01840103
| The STIMERM CANCEL function failed.
|
01840104
| An error occurred opening the mailman's queue.
|
01840105
| An error occurred closing the mailman's queue.
|
01850101
| An error was returned from the mailman.
|
01850102
| An error was returned from the mailman.
|
01850103
| The mailman abended.
|
01850104
| The mailman abended.
|
01850105
| The monitor subtask failed.
|
01850106
| The PowerExchange Agent is not active.
|
01850107
| An error occurred during a name/token RETRIEVE.
|
01850108
| Initialization for PowerExchange common services failed.
|
01900101
| Initialization for the module EDMCICIN failed.
|
01900102
| Termination for the module EDMCICIN failed.
|
01900103
| The mailman returned an error.
|
01900104
| A previous error occurred. For more information, see the previous error.
|
01900105
| The sync point 'begin phase 1' function failed.
|
01900106
| The sync point 'end phase 2' function failed.
|
01900107
| The logger stopped with abend U4094. The global directory (EDMSDIR) requested the abend.
|
01900108
| The PowerExchange Agent was not active during initialization.
|
01900109
| The PowerExchange Agent was not active during an OPEN call.
|
01910101
| An invalid function was received from the DB2 ECCR.
|
01910102
| No registration list was found for the table name.
|
01910103
| The registration routine returned an error.
|
01910104
| The module could not find a UOW entry, FREEUOW.
|
01910105
| The module could not find UOW entry, RECORD
|
01910106
| Sync point phase 1 failed.
|
01910107
| Sync point phase 2 failed.
|
01910108
| Initialization for the module EDMCICIN failed.
|
01910109
| Termination for the module EDMCICIN failed.
|
0191010A
| The PowerExchange Agent is not active.
|
0191010B
| The PowerExchange Logger is not available.
|
0191010C
| Error in resync processing (receiving outstanding UOWs from Logger)
|
0191010D
| Error in count of outstanding UOWs received from Logger
|
01920101
| A previous error occurred. For more information, see the previous error.
|
01920102
| An invalid function code was encountered.
|
01920103
| The INIT function was called twice.
|
01920104
| CIC was not called for initialization.
|
01920105
| The module could not find its entry in the UOW table.
|
01920106
| The module is not capturing the specified file.
|
01920107
| An invalid sync parameter was encountered.
|
01920109
| Initialization for the module EDMCICIN failed.
|
0192010A
| Termination for the module EDMCICIN failed.
|
0192010B
| The registration routine returned an error.
|
0192010C
| The mailman returned an error.
|
0192010D
| The PowerExchange Agent is not active.
|
01930101
| Initialization for the module EDMCICIN failed.
|
01930102
| Termination for the module EDMCICIN failed.
|
01930103
| The IMODULE GETMAIN function failed.
|
01930104
| The IMODULE LOAD function failed.
|
01930105
| The module was unable to get into a supervisory state.
|
01930106
| The module could not find the PowerExchange Agent SSCT.
|
01930107
| The module encountered an invalid agent control block.
|
01930108
| The module could not find the IMS SSCT.
|
01930109
| There are no DBDs to capture.
|
0193010A
| Initialization for the module $MSGX failed.
|
0193010B
| Termination for the module $MSGX failed.
|
0193010C
| The PowerExchange Agent is not active.
|
01940101
| The input vector for the calling program is too high.
|
01940102
| The module encountered an invalid UOW address.
|
01940103
| The PowerExchange Logger stopped, and the global options module (EDMSDIR) requested that the ECCR abend.
|
01960101
| An IMS ESS definition is required.
|
01970101
| The database is not registered for capture.
|
01970102
| The module was not passed the working storage address.
|
01970103
| A name/token RETRIEVE failed.
|
01970104
| Not an online region.
|
01990101
| No databases to capture.
|
01990102
| The module could not locate the DD name for the DBD in TIOT.
|
01990103
| An error occurred in locating JFCB.
|
01990104
| An error occurred when initializing the registration routine.
|
01990105
| An error occurred during in a GET function from the registration routine
|
019B0101
| The input vector for the calling program is too high.
|
019B0102
| The module encountered an invalid UOW address.
|
019B0103
| The PowerExchange Logger stopped, and the global options module (EDMSDIR) requested that the ECCR abend.
|
019D0101
| An IMS ESS definition is required.
|
01A00101
| A subsystem is required.
|
01A00102
| A global queue error occurred.
|
01A00103
| The $GENDCB module failed.
|
01A00104
| An OPEN function from the $GENDCB module failed.
|
01A00105
| A CLOSE function from the $GENDCB module failed.
|
01A00106
| An FREE function from the $GENDCB module failed.
|
01A00107
| The DD statement PWXEDMCC is missing.
|
01A00108
| The OPEN function failed.
|
01A00109
| SET STIMERM failed.
|
01A0010A
| STIMERM CANCEL failed.
|
01A0010B
| An error occurred while the module was connecting to PowerExchange common services.
|
01A0010C
| An XCF JOIN function failed.
|
01A0010D
| An XCF LEAVE function failed.
|
01A0010E
| An XCF DESTDEL function failed.
|
01A0010F
| An XCF GET function failed.
|
01A00110
| An XCF PUT function failed.
|
01A00111
| An XCF FREEBUFF function failed.
|
01A20102
| A global queue error occurred.
|
01A30101
| A CIC initialization error occurred.
|
01A30102
| A CIC termination error occurred.
|
01B70101
| The agent from the SSM member is not active.
|
01B70102
| The EDMSCTRL control block is invalid.
|
01B70103
| The program must run in an IMS control region.
|
01B70104
| There is a loop in the "ESAF add" routine.
|
01A30103
| An invalid IPC header was found in the record.
|
01C40101
| The input vector for the calling program is too high.
|
01C40102
| The module encountered an invalid UOW address.
|
01C40103
| The PowerExchange Logger stopped, and the global options module (EDMSDIR) requested that the ECCR abend.
|
01C70101
| An IMS ESS definition is required.
|