PWX- 04350

PWX-
04350

ERROR - PLOG Out of Sequence.
The PLOG file being added to the PCAT control file was created prior to the one that was last added. This indicates that two or more PLOG copy jobs have run in the wrong sequence, or that a database restore was run that has invalidated the PLOGS created after the point in time the restore has reset the database to.
Program ends with return code 8.
Contact computer operations and/or the DBA to establish the cause of the error. Use the 'D' delete function of the DTLCCADW utility to remove PCAT entries as necessary (the 'R' report function might facilitate the investigation). Add the PLOGs to the PCAT again in their correct sequence using the 'A' append function of DTLCCADW.