PWX- 06218

PWX-
06218

CCL Configuration: EXT_CAPT_MASK directory not accessible. CHKPT_BASENAME=(
path_mask
) System errno=<
error_number
>
PowerExchange cannot access or create the directory for storing the log files of the PowerExchange Logger for Linux, UNIX, and Windows. This directory is specified in the EXT_CAPT_MASK parameter of the pwxccl.cfg file.
In the message text,
system errno
is the error code returned from the directory call.
The PowerExchange Logger process fails to initialize.
Ensure that EXT_CAPT_MASK parameter specifies a valid path. Also, ensure that the PowerExchange Logger process has adequate permissions to create the directory if it does not exist.