PWX-04377

PWX-
04377

ADASEL output for plog
plog_file
contains a null SELHTRN. Record block number
block_number
. Time stamp of update
timestamp
When the PowerExchange Adabas ECCR ran the ADASEL utility, the utility returned output that included a null transaction number for a record. This problem occurs when the ECCR JCL is configured to capture change data for a source file with an Adabas spanned record.
The program stops with a non-zero return code.
Verify that the ADABAS load library contains the following SAG ZAPs that PowerExchange requires to capture changes for spanned records: AU823101 (ADA823), AU824072 (ADA824), AU825047 (ADA825), and AU826017 (ADA826).