PowerExchange for CDC and Mainframe
- PowerExchange for CDC and Mainframe 10.5.2
- All Products
Reason Code
| Explanation
|
---|---|
00000601
| An unknown error occurred.
|
00000602
| There is no schema registration.
|
00000603
| There is no relational schema registration.
|
00000604
| There is no object or schema that matches the specified EDMNAME.
|
00000605
| The object or schema is not active for the time requested.
|
00000702
| If message PWXEDM172702I is issued, then the Log Read task (EDMLCQO0) has been terminated because the PowerExchange Logger stole the active log it was using because no other active logs are available. Otherwise, the Log Read task (EDMLCQO0) in the PowerExchange Logger has abended.
|
00000703
| No logged‑on reader control block found for Terminate Process.
|
00000704
| Terminate Process request failed.
|
00000805
| Client Control Block not found (client not already or no longer signed on to Logger).
|
00000813
| Invalid XCF message (unrecognized encoded command).
|
00001506
| Data Is No Longer Available (no RBA range can be found).
|
00001507
| data is not present in inventory (requested timestamp does not yet exist).
|
00001508
| Data Not Accessed Due To Error (for example, attempt to attach subtask failed).
|
0000150A
| Log reader disconnected from Logger before initialization was completed.
|
00001510
| Tran Id Logger Name Not This Logger.
|
00001511
| No logged‑on reader control block found for Request Data Transfer.
|
00001514
| Stop location is before start location.
|
00001515
| No such start location found.
|
00001601
| No logged‑on reader control block found for Stop Data Transfer.
|
00001701
| Registration request failed for unknown reason.
|
00001702
| There are no database, data set, or subsystem registrations.
|
00001703
| There are no registrations of the specified type.
|
00001704
| There is no object or schema that matches the specified EDMNAME.
|
00001705
| The object or schema is not active for the time requested.
|
00001706
| The module cannot find the primary object profile for the object. Possible reasons include that the object is not defined to PowerExchange. For VSAM and IMS, this reason code can be generated if you create redefined records for a VSAM data set or an IMS segment, and then delete the primary record definition.
|
00001708
| Registration request for invalid object type.
|
00001901
| The PowerExchange Logger is shutting down.
|
00001902
| The PowerExchange Logger requires additional system resources.
|
00001903
| The queue could not be opened.
|
00001904
| Invalid signon request (requesting neither read mode nor write mode).
|
00001905
| Already signed on (duplicate jobname).
|
00001906
| An XCF connection failed.
|
00001907
| The PowerExchange Logger is not ready.
|
00001908
| Logger on different CPU (Log Reader attempted to connect to Logger that was running on a different operating system instance).
|
00001909
| Failed to add log reader control block (OUQQ).
|
0000190A
| Unable to start log reader subtask.
|
0000190B
| Could not log ECCR signon record.
|
0000190C
| Failed to add ECCR control block (INQQ).
|
0000190D
| Resume operation failed.
|
00002104
| Invalid Resource Interest List command
|
00002105
| Chain error processing IntLst command
|
00002111
| No matching signed on reader
|
00002501
| An unknown error occurred.
|
00002502
| An unsupported data type was found.
|
00002503
| A module found unsupported data definition language (DDL) code.
|
00002504
| An object registration was not found.
|
00002505
| A schema registration was not found.
|
00002506
| There is no schema for the specified time.
|
00002507
| A change request failed.
|
00002601
| Could not log user data record
|
00002806
| Column name with excessive length encountered.
|
00004701
| Member Logger was already in quiesced status.
|
00004702
| Member Logger was already in stopped status.
|
00004801
| Member Logger was not in quiesced status.
|
00004802
| Member Logger was already in stopped status.
|