Reason Codes 00000601 to 00004499 - Command

Reason Codes 00000601 to 00004499 - Command

PowerExchange issues reason codes from encoded commands that pass between program modules. Some of these reason codes are displayed in the messages that you see when an error occurs.
The following table describes these reason codes:
Reason Code
Explanation
00000601
An unknown error occurred.
00000602
There is no schema registration.
00000603
There is no relational schema registration.
00000604
There is no object or schema that matches the specified EDMNAME.
00000605
The object or schema is not active for the time requested.
00000702
If message PWXEDM172702I is issued, then the Log Read task (EDMLCQO0) has been terminated because the PowerExchange Logger stole the active log it was using because no other active logs are available. Otherwise, the Log Read task (EDMLCQO0) in the PowerExchange Logger has abended.
00000703
No logged‑on reader control block found for Terminate Process.
00000704
Terminate Process request failed.
00000805
Client Control Block not found (client not already or no longer signed on to Logger).
00000813
Invalid XCF message (unrecognized encoded command).
00001506
Data Is No Longer Available (no RBA range can be found).
00001507
data is not present in inventory (requested timestamp does not yet exist).
00001508
Data Not Accessed Due To Error (for example, attempt to attach subtask failed).
0000150A
Log reader disconnected from Logger before initialization was completed.
00001510
Tran Id Logger Name Not This Logger.
00001511
No logged‑on reader control block found for Request Data Transfer.
00001514
Stop location is before start location.
00001515
No such start location found.
00001601
No logged‑on reader control block found for Stop Data Transfer.
00001701
Registration request failed for unknown reason.
00001702
There are no database, data set, or subsystem registrations.
00001703
There are no registrations of the specified type.
00001704
There is no object or schema that matches the specified EDMNAME.
00001705
The object or schema is not active for the time requested.
00001706
The module cannot find the primary object profile for the object. Possible reasons include that the object is not defined to PowerExchange. For VSAM and IMS, this reason code can be generated if you create redefined records for a VSAM data set or an IMS segment, and then delete the primary record definition.
00001708
Registration request for invalid object type.
00001901
The PowerExchange Logger is shutting down.
00001902
The PowerExchange Logger requires additional system resources.
00001903
The queue could not be opened.
00001904
Invalid signon request (requesting neither read mode nor write mode).
00001905
Already signed on (duplicate jobname).
00001906
An XCF connection failed.
00001907
The PowerExchange Logger is not ready.
00001908
Logger on different CPU (Log Reader attempted to connect to Logger that was running on a different operating system instance).
00001909
Failed to add log reader control block (OUQQ).
0000190A
Unable to start log reader subtask.
0000190B
Could not log ECCR signon record.
0000190C
Failed to add ECCR control block (INQQ).
0000190D
Resume operation failed.
00002104
Invalid Resource Interest List command
00002105
Chain error processing IntLst command
00002111
No matching signed on reader
00002501
An unknown error occurred.
00002502
An unsupported data type was found.
00002503
A module found unsupported data definition language (DDL) code.
00002504
An object registration was not found.
00002505
A schema registration was not found.
00002506
There is no schema for the specified time.
00002507
A change request failed.
00002601
Could not log user data record
00002806
Column name with excessive length encountered.
00004701
Member Logger was already in quiesced status.
00004702
Member Logger was already in stopped status.
00004801
Member Logger was not in quiesced status.
00004802
Member Logger was already in stopped status.