PWX- 06980

PWX-
06980

CCT used by collector does not match Agent cache used by PowerExchange Logger.
Changes were found for a capture registration defined to the ECCR. However, when these changes were reported to the PowerExchange Logger, the PowerExchange Agent cache that is used by the PowerExchange Logger did not have a record of this registration.
ECCR ends with an error.
Check that DTLAMCPR in the repository PowerExchange Listener is the same as in the ECCR. PowerExchange Agent cache is refreshed only after the UPDATEINTERVAL is specified in the AGENTREP file. If new registrations have been created and updates captured for them, the PowerExchange Agent cache might not have the new registrations yet. Wait for UPDATEINTERVAL and then restart the ECCR.