Message Reference Volume 1

PWX- 06068

PWX-
06068

Controller: Error initializing tasks event table, rc =
return_code
.
An error occurred while the PowerExchange Condense was initializing the tasks event table that is used to allow communication among the Controller task, Command Handler subtask, and Condense task.
The Condense job ends.
Contact Informatica Global Customer Support. Identify the function that was being performed at the time of the error. On i5/OS, this message might be logged if an attempt is made to run two Condense jobs concurrently. In this case, the second job might not be able to access the message queues that are locked by the first job. Check whether another instance of the Condense jobs is still running.