PWX- 06449

PWX-
06449

The CDCT cannot be fully synchronized with the checkpoint file because of missing resources. Continue? (Y/N)
On a z/OS or i5/OS system, this message is issued as a operator message that requires a reply of Y or N to indicate whether to continue or end PowerExchange Condense processing after synchronization of the checkpoint file to the CDCT file reports that some records could not be synchronized. See the preceding PWX-06446 messages to determine which records are missing from the CDCT file after synchronization. Synchronization occurs at PowerExchange Condense initialization.
The system waits for a reply to the operator reply prompt.
Reply Y if it is acceptable that the records are missing from the CDCT file and not available to determine some of the condense files for extraction processing. For example, the records might be associated with condense files that contain old data. With this reply, PowerExchange Condense processing continues, and change data in the condense files to which the missing records point is not extracted. Reply N if you want PowerExchange Condense processing to end. You can then restore the CDCT file to appropriate point or perform a cold start to prevent change data loss.