Message Reference Volume 1

PWX- 04502

PWX-
04502

Error
error code
opening condensed data captured table
CDCT file name
.
The task was unable to open the CDCT file. On z/OS,
file name
is the z/OS DDNAME DTLCACDC. On i5/OS,
file name
is the data library and file name. On z/OS, the problem might occur if DDNAME DTLCACDC was not present (or allocated to DUMMY) in the PowerExchange Listener JCL or in the DBMOVE JCL if the from location is LOCAL. On i5/OS, either the specified file might not exist or it cannot be opened because of access permissions.
The request fails.
Locate the CDCT file. If it does not exist, create a new CDCT file and initialize it as described in the adaptor documentation so that it has the correct record length, key length and trailer record. If the CDCT does exist, create an NRDB map and do a Row Test on it through the PowerExchange Navigator. If the problem cannot be determined, contact Informatica Global Customer Support.