PWX- 06147

PWX-
06147

IMSID
In the DBMOVER configuration file, the
imsid
parameter in the IMSBSDS statement contains an error. The parameter specifies an IMS ID value that is longer than the maximum length of 4 bytes. This parameter value is used by z/OS PowerExchange Listener and IMS collector jobs.
Processing ends.
Correct the parameter value to specify an IMS ID value of 4 bytes or less.