PWX- 05227

PWX-
05227

DBD
dbdname
not found in specified library
pds_name
or IMS catalog for
ims_ssid
.
When trying to import an IMS database description (DBD) into a data map, PowerExchange did not find the DBD in either the specified library or the IMS catalog for the specified IMS subsystem. PowerExchange searched the library first because the IMSBSDS statement that corresponds to the IMS SSID in the DBMOVER file is configured to search the library and then the IMS catalog.
The task terminates.
In the
Import Copybook - Remote Details
dialog box, specify a
HLQ.PDS_NAME
(
dbdname
) value that points to the correct DBD location. With this value, both the library and catalog can be searched.