The following table lists the reason codes issued by the PowerExchange utilities:
Reason Code
Explanation
01440600
The DCB failed to open properly.
01440601
The PowerExchange Logger interface utility (EDMXLUTL) could not generate a required DCB.
01440602
The PowerExchange Logger interface utility (EDMXLUTL) could not open a data set.
01440603
The PowerExchange Logger interface utility (EDMXLUTL) could not close a data set.
01440604
The PowerExchange Logger interface utility (EDMXLUTL) could not free a data set.
01440609
A control card error was detected.
01450605
The event command processor was (EDMXLEVT) unable to obtain working storage.
01450606
The event command processor (EDMXLEVT) was unable to load the log utility process module.
01450607
A bad PowerExchange standard record was detected.
01450608
A bad PowerExchange canonical record was detected.
01450618
A PUT function for the output queue failed.
0145061B
The conversion buffer is too small.
01450624
A LOAD function failed for the event command processor (EDMXLEVT).
01450625
The build command service did not return an PowerExchange record.
01450626
The event command processor (EDMXLEVT) could not find any active EDMNAMEs for data capture.
01450627
Excessive number of descriptions (more than 5) to be added to event marker (from EDMXLEVT)
0145062E
The event command processor (EDMXLEVT) could not initialize the log utility because a previous failure occurred.
01450651
A RETURN EDMNAME call failed.
01450652
A DB2 request for a list of table names failed.
01460605
The build command utility (EDMXIBCM) was unable to obtain working storage.
01460619
A bad encoded command was passed to the build command utility (EDMXIBCM).
0146061A
No conversion buffer was passed to the build command utility (EDMXIBCM).
0146061B
The conversion buffer is too small.
0146061C
The conversion buffer length is zero.
0146061D
The conversion buffer has a bad header record.
0146061E
No worklist buffer was passed to the build command utility (EDMXIBCM).
0146061F
The worklist buffer is too small.
01460620
The worklist buffer length is zero.
01460621
The worklist buffer has a bad header record.
01460622
A BUILD function failed for a pipe cleaner.
01460623
A BUILD function failed for process termination.
01460625
The build command utility (EDMXIBCM) did not return an PowerExchange record.
01460626
A BUILD function fail for a registration list.
01460627
The data set name is missing for a registration list request.
01460629
The build command utility could not locate a database descriptor.
0146062C
A bad return code was received from a registration list request.
0146062D
The request type entered is not supported by the command module.
0146062F
The requested object category is invalid.
06030646
A TESTCB function failed for the ACB.

0 COMMENTS