PWX- 06131

PWX-
06131

PWXCCL configuration error: CAPTURE_NODE_PWD and CAPTURE_NODE_EPWD parameters are mutually exclusive.
Both the CAPTURE_NODE_PWD and CAPTURE_NODE_EPWD parameters are specified in the pwxccl.cfg configuration file for the PowerExchange Logger for Linux, UNIX, and Windows. Only one of these parameters is allowed.
The PowerExchange Logger process fails to initialize.
Remove or comment out either the CAPTURE_NODE_PWD parameter or the CAPTURE_NODE_EPWD parameter. Alternatively, you can remove both parameters because they are optional.