PWX- 05228

PWX-
05228

DBD
dbdname
not found in IMS catalog for
ims_ssid
. No library name specified for alternate search.
When trying to import an IMS database description (DBD) into a data map, PowerExchange did not find the DBD in the IMS catalog. The IMSBSDS statement that corresponds to the specified IMS SSID in the DBMOVER file is configured to search the IMS catalog and then a library. However, PowerExchange did not search the library because no library PDS name is specified for the import operation.
The task terminates.
In the
Import Copybook - Remote Details
dialog box, to search both the IMS catalog and an alternate library PDS, specify the DBD location as
HLQ
.
PDS_NAME
(
dbdname
) .