Hi, I'm Bolo!
What would you like to know?
ASK BOLOPreview
Please to access Bolo.

Table of Contents

Search

  1. Preface
  2. PWX-00000 to PWX-00099
  3. PWX-00100 to PWX-00999
  4. PWX-01000 to PWX-01999
  5. PWX-02000 to PWX-04999
  6. PWX-05000 to PWX-06999
  7. PWX-07000 to PWX-09999
  8. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 1

Message Reference Volume 1

PWX- 06809

PWX-
06809

DB2 for i5/OS CDC has generated missing NR entry because ALWNONRENT=Y specified.
When the journal receiver becomes full, PowerExchange CDC for DB2 for
i5/OS
requires a next receiver (NR) entry to continue processing to the next receiver in the chain.
i5/OS
does not always provide NR entries in journal receivers. To prevent the capture task from failing when i5/OS does not provide an NR entry, the ALWNONRENT=Y parameter is specified in the AS4J CAPI_CONNECTION statement. With this parameter setting, PowerExchange generates an NR entry for internal use to allow CDC processing to continue. The generated NR entry is not placed on the actual journal receiver.
Capture processing continues.
No response is required.