PWX- 07255

PWX-
07255

CCIMT: The IMS ECCR cannot read change data from the overflow log record X07, key<
key
>. Return codes=
return_code1,return_code2,return_code3
The IMS ECCR cannot read change data from the overflow log record that has the specified key.
The RECON data sets contain different types of records, one of which is the X'07' record. The information in this type of record can be stored in a single record or in multiple records.
In the message text:
  • key
    is key of the overflow record.
  • return_code1
    ,
    return_code2
    , and
    return_code3
    are PowerExchange return codes for the failure.
The IMS ECCR ends.
Verify that the RECON data set is correct. Because the read failed, something could be wrong with the data set.