PWX- 04631

PWX-
04631

Logger file
file_name
record
record_number
length
bytes
. Change type
type
. Time stamp
time_stamp
. Tag
registration_tag
.
The extraction of change data from a PowerExchange Logger for Linux, UNIX, or Windows or the DTLCACON program log file failed. The PowerExchange Listener is using the CAPX or CAPXRT access method to extract source data. This problem can occur when a record is inconsistent with the extraction map. This message provides information about the error, including the log file and record where the failure occurred, the type of change being extracted, and the registration tag name for the source object.
The extraction fails.
To diagnose the error, see accompanying messages. To identify the problematic records in the PowerExchange Logger log files, use the PWXUCCLPRT utility. Then send the information to Informatica Global Customer Support.