Hi, I'm Bolo!
What would you like to know?
ASK BOLOPreview
Please to access Bolo.

Table of Contents

Search

  1. Preface
  2. PWX-00000 to PWX-00099
  3. PWX-00100 to PWX-00999
  4. PWX-01000 to PWX-01999
  5. PWX-02000 to PWX-04999
  6. PWX-05000 to PWX-06999
  7. PWX-07000 to PWX-09999
  8. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 1

Message Reference Volume 1

PWX- 06940

PWX-
06940

Batch logs: Initial query with StartTime=<
time
> loc=<FIRST|NEXT|SPEC> SSID=<
job_name
>.
This message displays, for an IMS batch system, the parameters in the first IMS log-based ECCR query to the DBRC API for the SLDS logs. The ECCR reads data from the SLDS logs for change data capture. The parameters are:
  • StartTime
    timestamp
    . The start timestamp that is used as a basis of the search for the requested log. The timestamp is a packed decimal timestamp in UTC format.
  • Loc
    option
    . An option that is used to search for the log based on the start time:
    • SPEC. The log with the specified start time.
    • PREV. The log with the start time prior to the specified start time.
    • NEXT. The log with the start time that follows the specified start time.
  • SSID
    job_name
    . The IMS batch job that is associated with the log that is being queried.
These parameters correspond to DBRC log query request parameters. For more information, see the IBM DBRC API programming documentation.