PWX- 06217

PWX-
06217

CCL Configuration: CHKPT_BASENAME directory not accessible. CHKPT_BASENAME=(
path_basename
) System errno=<
error_number
>
PowerExchange cannot access or create the directory for storing the generated checkpoint files for the PowerExchange Logger for Linux, UNIX, and Windows. This directory is specified in the CHKPT_BASENAME parameter of the pwxccl.cfg file.
In the message text,
system errno
is the error code returned from the directory access attempt.
The PowerExchange Logger process fails to initialize.
Ensure that the CHKPT_BASENAME parameter specifies a valid path. Also, ensure that the PowerExchange Logger process has adequate permissions to create the directory if it does not exist.