Message Reference Volume 1

PWX- 07754

PWX-
07754

eccr_name
, ECCR,
current_system_time
, Registration, DB:
database_name
, Name:
registration_name
, suspension violation, uow time
uow_time
, suspension time
suspension_timestamp
, capture image time
change_record_timestamp
.
A change record for a suspended capture registration is in a unit of work (UOW) that started before the suspension window. The suspension timestamp indicates when the suspension window began. This situation is not valid and might compromise data integrity.
The
eccr_name
is the ECCRNAME value specified in the ECCR parameters.
The
registration name
is the user-defined registration name with the registration version appended.
Processing ends or continues depending on the setting for the ON_SUSPENSION_ERROR_CONTINUE parameter in the ECCR configuration file.
No response is required.