PWXEDM177025 W

PWXEDM
177025
W

READS call time,
seconds
seconds, exceeds threshold (
call
call RBA
rba
)
The time to complete a READS DB2 API call exceeds the current threshold.
  • For an F call, the RBA value is the point at which DB2 was requested to start delivering log data.
  • For an N call, the RBA value is the last log record delivered and the point at which DB2 should continue delivering log data.
  • For any other call, the RBA has no meaning.
Processing continues.
Look at the DB2MSTR address space for messages with corresponding time stamps. The following messages contain additional information.