Message Reference Volume 3

Message Reference Volume 3

PWXEDM 172887 E

PWXEDM
172887
E

EDP is not receiving control from the DBRC Interface, DATA CAPTURE IS STOPPED
The DBRC interface, that is used by PowerExchange, cannot receive control.
The IMS ECCR continues the startup process and the PowerExchange change capture process is turned off.
Check the DBRC address space to verify that the correct libraries are in the DBRC region.