PWXEDM 172637 E

PWXEDM
172637
E

Restart Log Manager unable to initialize
restart_ddname
The PowerExchange Logger for z/OS was unable to initialize the emergency restart data set that is allocated by the specified DD name. The ddname is either ERDS01 or ERDS02.
The task ends abnormally with user abend code U3035 and reason code X'FFFF00xx'.
Verify that you specified the correct PowerExchange Logger emergency restart data sets in the JCL. If the problem persists, get the job step listing. Then contact Informatica Global Customer Support.