Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL5008
  3. DTL58001 to DTL62569
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175050
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 177196 W

PWXEDM
177196
W

TRACE(MONITOR) CLASS(1) IS INACTIVE
The DB2 ECCR issued an IFCID 306 READS call but received reason code x'00E60832'. This reason code indicates that the IFCID required for the READS call is not active. The IFCID is usually activated when the DB2 ECCR initializes and issues the DB2 'START MONITOR(TRACE) CLASS(1)' command. In this case, another DB2 command might have stopped the trace.
When the DB2 ECCR detects this condition, it issues this message and restarts the trace.
No response is required because the DB2 ECCR usually restarts the required trace. If the ECCR cannot restart the trace, it abends.

0 COMMENTS

We’d like to hear from you!