PWXEDM 172047 W

PWXEDM
172047
W

module
: MVS Logger operation failed for stream name
stream_name
, Code=
return_code
, Rsn=
reason_code
A module encountered an error while attempting to connect to a MVS system logger stream using the IXGCONN macro to generate the specified stream name. The PowerExchange Agent attempted to connect to a MVS system logger stream, because the SysplexLogDays startup parameter for the PowerExchange Agent, which specifies the retention period for messages in the PowerExchange sysplex message log, was non-zero.
It is possible that the MVS system is not in a parallel sysplex or that the stream name is not defined for the MVS system logger component.
The PowerExchange Agent stops its attempts to record messages in the PowerExchange sysplex message log, but the PowerExchange Agent message logging into the PowerExchange Agent EDMSLOG data set continues.
Verify that the PowerExchange sysplex message log is correctly set up. For more information about the IXGCONN return and reason codes, see the IBM MVS programming documentation for your MVS version. Contact Informatica Global Customer Support.