Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL5008
  3. DTL58001 to DTL62569
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175050
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 172663 I

PWXEDM
172663
I

Logger received
sync_record_type
record without corresponding begin_UOW record for UOW
uow_ID
The PowerExchange physical logger received a begin_sync_PH1, begin_sync_PH2, or end_sync_PH2 record for the specified UOW. However, a begin UOW record does not exist for this UOW. The PowerExchange Logger requires a begin_UOW record before it can recognize a begin_sync or end_sync record.
The PowerExchange Logger ignores the sync record for this UOW and continues processing.
To determine the cause of the error, check the JES2 log for previous messages from the PowerExchange physical logger. If the problem persists, get the job step listing and contact Informatica Global Customer Support.