PWXEDM 177460 E

PWXEDM
177460
E

TABLE
creator
.
table_name
unexpected row length in {normal|before} image
While the DB2 for z/OS ECCR was processing a DB2 log record for the specified table, it encountered an invalid row length.
The ECCR abends or continues processing, as indicated in the message PWXEDM177030E.
Ensure that the UOWs for the specified table do not include both DDL and DML operations. The ECCR does not support both types of operations in the same UOW for the same table. Also, collect the complete ECCR job listing, including the SYSUDUMP output. Then contact Informatica Global Customer Support.