Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL5008
  3. DTL58001 to DTL62569
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175050
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 172633 E

PWXEDM
172633
E

Logger restart data set ERDS02 is empty
The PowerExchange Logger for z/OS requires at least one emergency restart data set (ERDS) to operate. The dual data set allocated to ERDS02 is empty.
Processing continues with only the primary ERDS.
Check the PowerExchange Logger ERDS02 DD statement in the PowerExchange Logger JCL to verify that it specifies a valid restart data set that exists.

0 COMMENTS