Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL5008
  3. DTL58001 to DTL62569
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175050
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 172662 E

PWXEDM
172662
E

Logger was unable to {ADD | DELETE | FIND} UOW
uow_ID
to internal table
When the PowerExchange physical logger received a begin UOW record for the specified unit of work (UOW), it could not add, delete, or find the UOW in the internal table.
The PowerExchange Logger ends.
To determine the cause of the error, check the JES2 log for previous messages from the PowerExchange physical logger. If the problem persists, get the job step listing and contact Informatica Global Customer Support.

0 COMMENTS

We’d like to hear from you!