is the VSAM ECCRs interpretation of the VSAM error information. A register 15 value of 8 and an RPLERRCD of 92 (5C) usually indicates an out‑of‑sync condition between the primary and alternate control data sets (CDSs). Action varies according to the type of VSAM error.
If the message is considered a warning, the request continues. Otherwise, The batch VSAM ECCR aborts the request.
See the appropriate IBM VSAM manual for a complete description of the return codes to help you diagnose the error. If you cannot correct the error, contact Informatica Global Customer Support.
In the case of a RPLERRCD of 92 (5C), compare the primary and alternate CDSs to identify any differences. If you determine that one data set is missing some of the records that exist in the other, use IDCAMS to delete/define the smaller data set, and then REPRO the larger. If you are unable to verify that one CDS is complete, you may need to combine the records in both to build a new CDS that contains all records.