PWXEDM 172503 E

PWXEDM
172503
E

Logger Current RBA=
current_RBA
is less than requested RBA=
requested_RBA
The current PowerExchange Logger for z/OS writing position in the logs is before the starting relative byte address (RBA) that the log reader task requested.
The log reader task ends but Logger processing continues.
Correct the requested RBA of the log read processor (LRP).