Message Reference Volume 3

PWXEDM 172649 I

PWXEDM
172649
I

Logger Offload handler will attempt to continue with active log copy 2
The PowerExchange Logger offload handler was unable to allocate copy1 of the active log data set. If dual active logging is in effect, the PowerExchange Logger offload handler tries to continue by switching to copy 2 of the active log data set.
If the attempt to switch to copy 2 fails or if dual active logging is not in effect, the PowerExchange Logger ends the offload process.
To determine the cause of the problem, check the JES2 log for previous messages from the PowerExchange physical logger. If the problem persists, get the job step listing and contact Informatica Global Customer Support.