Message Reference Volume 3

PWXEDM 172716 E

PWXEDM
172716
E

error_description
for
keyword_name
‑ found
value_found
The indicated value of the keyword [ERROR DESCRIPTION | KEYWORD NAME | VALUE FOUND] must conform to a special format, such as data set name or time stamp. The value entered was not acceptable. This message is issued as a WTO message.
The PowerExchange Logger stops processing the current command set.
Correct the command and resubmit it. If necessary, read the keyword description in the manual to insure that the data format is acceptable. A time-stamp value must be specified as
YYDDD
/
HHMMSST
where
YYDDD
is a valid Julian date and
HHMMSST
is a valid time. Using tenths of seconds is optional. DRRN values must begin with ‘04’ or ‘08’. An IMS log code value must be in the range “AO’ to “FF”.