PWXEDM 172660 I

PWXEDM
172660
I

Logger ARCHIVE_LOG command terminated. Current active log data set is the last available
The PowerExchange Logger for z/OS rejected the ARCHIVE_LOG command because the current active log is the last available active log data set.
The PowerExchange Logger ends command processing. If you do not correct this situation, the PowerExchange Logger issues warning messages as the available log data space reaches critically low levels. When the active log becomes full, a final message indicates that there is no active log, and the PowerExchange Logger halts processing until you make active log space available.
Take the steps required to complete other waiting offload tasks. After you make another active log available (reusable) by completing the offload process for that log, command processing for the current active log can proceed.