Message Reference Volume 3

Message Reference Volume 3

PWXEDM 177450 E

PWXEDM
177450
E

Table
creator
.
table_name
DDL and DML in UOW
uowid
.
data_sharing_member_id
.
The DB2 for z/OS ECCR detected that a UOW performed both DDL and DML operations on the same table. The ECCR does not capture changes from UOWs that contain both types of operations on the same table.
The ECCR continues processing but might not capture some changes for the table.
Ensure that the UOWs for the specified table do not perform both DDL and DML operations.