Message Reference Volume 3

PWXEDM 172628 E

PWXEDM
172628
E

condition
invalid format for
ddname
data set
The PowerExchange Logger for z/OS failed because an invalid condition was detected for the emergency restart data set (ERDS) defined by the specified DD in the Logger JCL. In the message text:
  • condition
    is one of the following values: SYSOUT/SYSIN, NULL FILE, or TEMPORARY.
  • ddname
    is either ERDS01 or ERDS02.
The PowerExchange Logger ends abnormally.
Ensure that the ERDS01 and ERDS02 DD statements in the JCL specify valid data sets. Then run the job again.