Message Reference Volume 3

PWXEDM 172652 E

PWXEDM
172652
E

Logger internal DEFINE_LOG command failed for DSNAME=
dsname
The PowerExchange Logger offload processor encountered an error while attempting to update the PowerExchange Logger emergency restart data set (ERDS) with the new archive data set information.
The PowerExchange Logger ends the offload process. If the error is from the offload handler, the PowerExchange Logger ends the archive process.
To determine the cause of the problem, check the JES2 log for previous messages from the PowerExchange physical logger. If the problem persists, get the job step listing and contact Informatica Global Customer Support.