A member Logger job that is part of the Post-Log Merge process ended while processing data for the specified log reader. The Post-Log Merge task continues to merge data from that member Logger until it reaches the end of the data. The Post-Log Merge task then does not merge new data from that member Logger until the member Logger signs back on to the Post-Log Merge task. The member Logger signon will be indicated by message PWXEDM172141I.
This message is issued once for each active log reader that was receiving data merged from the member Logger. The message text includes the job name of the member Logger, the SMF ID of the system on which the member Logger ran, and the name of the log reader whose status has been changed to recognize that the member Logger is no longer active.
The Log Merge Facility (LMF) continues processing.
If the termination of the member Logger was expected, such as during a shutdown for an IPL of the system, no user action is required. If the termination was unexpected, determine the reason for the termination, correct the problem, and then try to restart the member Logger. If the problem cannot be diagnosed, or if the member Logger cannot be restarted, contact Informatica Global Customer Support.