Message Reference Volume 3

Message Reference Volume 3

PWXEDM 177372 W

PWXEDM
177372
W

Table '
creator.
table_name
' inconsistent definitions
The DB2 ECCR attempted to get a description of the specified table from the DB2 catalog. However, the description was inconsistent. This situation can occur when DDL activity is updating the catalog descriptions at the same time the DB2 ECCR is trying to access the descriptions.
The DB2 ECCR abends.
Look for prior messages in the DB2 ECCR output that concern this table. Then perform the actions that these messages suggest.