Message Reference Volume 3

PWXEDM 177445 E

PWXEDM
177445
E

INVALID STATUS (
status
) ENCOUNTERED FOR UOW
uow_id
.
data_sharing_member_id
The specified UOW has a DB2 ECCR internal status that is not valid at some point in CDC processing. The
status
variable represents one of the following values:
  • ABORT. The UOW was aborted, and no change data is available to capture.
  • OPEN. Change data is available to capture, but no Begin UOW record has been received.
  • POTENTIAL. The Begin UOW record has been received, but no change data is available to capture yet.
  • ROLLBACK. The UOW was rolled back, but change data is available to capture.
  • TRANSMIT. The DB2 ECCR is sending change data for the UOW to the PowerExchange Logger for z/OS.
  • UNRESOLVED. No
    urid
    value was encountered during the DB2 ECCR run. The ECCR records a URID value of PENDING for the specified UOW. When a UOW is outstanding, PowerExchange issues message PWXEDM177440W. This situation can occur if in‑flight units of work exist when the previous occurrence of the DB2 ECCR is shut down, usually without specifying QUIESCE.
The DB2 ECCR ends abnormally.
Contact Informatica Global Customer Support. Provide Support with the complete DB2 ECCR job listing, including the SYSUDUMP output.