PWXEDM 172777 E

PWXEDM
172777
E

Logger received
record_type
record with no Begin_UOW from ECCR
eccr_name
for UOW
uow_ID
, SEQ=
sequence_number
The PowerExchange Logger for z/OS issues this error message each time it receives a record from an ECCR without a corresponding begin UOW record for a UOW.
In the message text:
  • record_type
    is one of the following values:
    • BEGIN_PH1
      . begin‑phase‑1 record.
    • BEGIN_PH2
      . begin‑phase‑2 record.
    • END_PH2
      . end‑phase‑2 record.
    • CHANGE
      . change record.
  • eccr_name
    is the name of the ECCR.
  • uowID
    is the UOW ID of the UOW that was assigned by the ECCR.
  • sequence_number
    is the ECCR‑assigned sequence number for the record.
This message is issued as a WTO message and is written to the EDMSLOG file of the PowerExchange Agent.
Check the JES2 log for previous messages from the PowerExchange Logger. Also examine the previous messages for the ECCR. If you cannot diagnose the problem, collect the job step listings and contact Informatica Global Customer Support.