Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL5008
  3. DTL58001 to DTL62569
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175050
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 172783 W

PWXEDM
172783
W

Logger temporarily in single log mode, using [primary | secondary] log
active.log.dataset.name
The Physical Logger encountered an error when trying to allocate or initialize an active log data set. Messages will have been issued previously to identify exactly what type of problem occurred. This message will only be issued if dual logging has been specified for active log data. The message identifies which data set is used as the active log data set, and whether that is the primary or secondary active log.
The Logger will temporarily switch to single logging mode, but will continue operating normally otherwise. The Logger will resume dual logging mode when it switches to the next pair of active logs, assuming that both the primary and secondary active logs can be allocated and initialized.
Investigate the earlier messages that indicate why the primary or secondary active log could not be used, and take any corrective action they indicate. If you cannot correct the problem, contact Informatica Corporation Product Support.

0 COMMENTS

We’d like to hear from you!