PWXEDM 177387 E

PWXEDM
177387
E

TABLE
creator
.
table_name
DOES NOT EXIST IN CAPTURE DIRECTORY.
The DB2 for z/OS ECCR cannot find a description of the specified table in the capture directory tables.
The ECCR abends.
Ensure that only the ECCR or the capture directory utility updates the capture directory tables. You can bypass this problem by deleting the capture registration for the table and then deleting the row for this table in the TCAPTABLES table. Then restart the ECCR, re-create the capture registration, and refresh the ECCR.