Message Reference Volume 3

PWXEDM 172048 E

PWXEDM
172048
E

module
: MVS Logger Connect failed for stream name
stream_name
, Code=
return_code
, Rsn=
reason_code
A module encountered an error while attempting to perform a MVS logger operation using the PowerExchange sysplex message log.
The PowerExchange Agent stops its attempts to record messages in the PowerExchange sysplex message log, but the PowerExchange Agent message logging into the PowerExchange Agent EDMSLOG data set continues.
If the MVS logger operation is IXGCONN, IXGDELET, IXGBRWSE, or IXGWRITE, see the IBM MVS programming documentation for your MVS version for more information about the return and reason codes for the operation. Correct any environmental problems, then restart the PowerExchange sysplex message log by stopping and restarting the LOG subtask of the PowerExchange Agent. Contact Informatica Global Customer Support.