Message Reference Volume 3

Message Reference Volume 3

PWXEDM 172643 E

PWXEDM
172643
E

Physical Logger received a RC=
return_code
RSN=
reason_code
from {DSPSERV|HSPSERV} {CREATE|SREAD|DELETE|RELEASE} macro for LOG
log_dataset_name
The PowerExchange physical logger received an invalid return code from an internal macro for the specified log data set.
The task ends abnormally with user abend code U3035 and reason code X'F9FF00xx'.
Identify the z/OS data in the virtual (DIV) macro that is causing the problem. If necessary, correct it.