Message Reference Volume 3

Message Reference Volume 3

PWXEDM 172557 E

PWXEDM
172557
E

Logger
command_name
command failed for
logger_dataset
,
failure_reason
The PowerExchange Logger was processing a command for an active or archive log data set, when it determined that the command could not be processed. The command being processed, the data set name upon which the command was operating, and a description of the problem encountered, are all included in the text of the message.
Where:
  • command_name
    =
    DELETE_LOG
  • failure_reason
    is one of the following values:
    • data set not found in any restart data set
    • deletion of current active log not permitted
    • deletion of active log not needing archival not permitted
For example:
Logger DELETE_LOG command failed, for EDMUSR1.EDMTEST.DBML.SECLOG.DS94, dataset not found in any restart dataset
-or-
Logger DELETE_LOG command failed, for EDMUSR1.EDMTEST.DBML.SECLOG.DS04, deletion of current active log not permitted
-or-
Logger DELETE_LOG command failed, for EDMUSR1.EDMTEST.DBML.PRILOG.DS04, deletion of active log needing archival not permitted
The command processing ends.
PowerExchange Logger processing continues normally.
Examine the description of the problem that was encountered, and see if there was an error in the command that was issued, which could be corrected. For example, if you are trying to delete an archive log data set (using the DELETE_LOG command) but you have entered the data set name incorrectly, reenter the command with the correct data set name. If you cannot correct the problem, contact Informatica Global Customer Support.